Permissible as single fastening. Permissible load in cracked and non-cracked normal concrete of strength ≥ C20/25. Manufacturer’s information has to be observed strictly (ETA-06/0271).

data sheet
galvanized, according to DIN EN ISO 19598 / DIN EN ISO 2081
lengthLminMinimum drilling depthdiameterdiameterPzul permissible tractive forcePzulR30 permissible tensile load under the influence of fire (30min)PzulR90 permissible tensile load under the influence of fire (90min)weight
SAZ 68-13 mm43 mm12 mm6 mm2,4 kN1,0 kN0,4 kN3,2 kg/100
SAZ 811-17 mm43 mm10 mm8 mm1,6 kN0,9 kN0,7 kN1,4 kg/100
SAZ 1013-19 mm43 mm12 mm10 mm3,0 kN2,3 kN1,1 kN1,9 kg/100
SAZ 1215-21 mm43 mm14 mm12 mm3,6 kN2,8 kN1,4 kN2,6 kg/100
Stainless steel, according to ASTM 31 Ti / AISI 316 L, BS 320S17 / BS 316S11
lengthLminMinimum drilling depthdiameterdiameterPzul permissible tractive forcePzulR30 permissible tensile load under the influence of fire (30min)PzulR90 permissible tensile load under the influence of fire (90min)weight
SAZ 8E411-17 mm43 mm10 mm8 mm1,6 kN0,9 kN0,7 kN1,4 kg/100
SAZ 10E413-19 mm43 mm12 mm10 mm3,0 kN2,3 kN1,1 kN1,9 kg/100
SAZ 12E415-21 mm43 mm14 mm12 mm3,6 kN2,8 kN1,4 kN2,6 kg/100